9 November 2026
How to size latrine and water point ratios from a weekly structure count

A registration round tells you exactly how many people are in a site, down to the household. It also takes weeks to run, and by the time the numbers are clean, the site has moved on. If new arrivals are putting up shelters faster than anyone can enrol them, you need a way to keep the latrine and water point math roughly current between rounds. A structure count gives you that.
Getting from tents to people
The logic is just multiplication. You already have, or can estimate from the last registration round, an average household size for the population in that site, say five people per shelter. Multiply that by however many shelters are standing this week and you have a working population figure, structure by structure, section by section.
The shelter count is the piece that changes week to week. A site that looked settled last month can add forty or fifty new structures in a week during a surge, and that's forty or fifty households that haven't hit a registration list yet but are already drawing water and using the ground as a latrine. Counting new tents and spontaneous shelters from weekly imagery is exactly the gap this fills: it gives you a current shelter total and flags where the new ones went up, so your population estimate for WASH planning doesn't lag the registration cycle by a month.
Applying the Sphere ratios
Once you have a population figure per site or per section, the Sphere Handbook gives you the ratios to size against:
- No more than 20 people per shared latrine, with separate facilities for women and men and a recommended higher share of latrines for women given queuing and safety patterns.
- No more than 250 people per water point (tap stand or similar), sized so queuing time stays under 30 minutes.
- A minimum of 15 litres of water per person per day, which drives storage and trucking volume even where the number of taps looks adequate on paper.
Run your estimated population through those ratios and you get a straightforward build list. At 2,000 people and the 20:1 latrine ratio, you're planning for at least 100 latrine slabs, split by gender; at the 250:1 water point ratio, at least 8 functioning taps. The ratios aren't the hard part. Knowing the population to run them against, section by section, every week rather than once a month, is.
Where this breaks down without a current count
Two failure modes show up constantly in sizing work. The first is undercounting a fast-growing section because the last registration still reflects the site before a push of new arrivals, so the latrine and water point numbers look fine on a spreadsheet while one corner of the camp is badly short. The second is overbuilding in a section that has thinned out. People drift to a different block or leave the site, and infrastructure gets sized against a population that's no longer there.
A weekly shelter count, broken out as new structures and a running total per section, lets you catch both. It won't tell you household size or vulnerability breakdowns, that's still registration's job, but it tells you where the shelter footprint is growing or shrinking right now, which is the number your latrine and water point math actually runs on between registration rounds.
If you're sizing a response and don't want to wait on the next full survey to know how many shelters are standing right now, Displacement Monitoring turns weekly imagery into a structure count and a change layer, as a map or a CSV, so the population figure behind your WASH ratios stays current.
Run your next structure count against the Sphere ratios before you order the next round of slabs and tap stands.